DIGITAL BLACK BOX (V.I.P) INSTALATIONS


WIRING:
TERMINAL l:- 12 VOLTS DC POSITIVE - NO: 14 WIRE
TERMINAL 2:- 12 VOLTS DC NEGATIVE 7 - NO: 14 WIRE
TERMINAL 3:- TO BONDING GROUND - NO: 10 WIRE
TERMINAL 4:- TO GURDIES - NO: 10 WIRE
CROSS CONNECT GURDIES - NO: 10 WIRE


OPERATIONS:

SWITCH POSITIONS
     OFF -
TURNS UNIT OFF
     NAT. -


USED TO GIVE NATURAL LINE READING ON METER
IF READING IS LOW BELOW (. 700V) LINES IN WATER
INDICATES LOW ZINC ACTION GURDIES NOT
INSULATED PROPERLY OR LEAKAGE THRU SALT BUILD IJP
ON GURDIE BASES


     CONT. -


SHOWS CONTROLLED LINE VOLTAGE ADJUSTED USING
CONTROL KNOB
ADJUST LINE VOLTAGE BETWEEN .550 VOLTS TO .600
VOLTS FOR KINGS LARGER FISH LOWER READING


     PULSE -


USED DURING SRATCH FISHING CONDUCTIONS
ADJUST LINE READING WHEN LIGHT IS ON
UNIT WILL CONTROL VOLTAGE FOR PREDETERMINED
TIME AND THEN ALLOW NATURAL READING T0 RAMP
UPWARD THEN RETURN CONTROL VOLTAGE


     LIGHT - 


INDICATES WHEN LINE READING IS BEING CONTROLLED

 

NOTES:

 

  • INSURE GURDIES ARE PROPERLY INSULATED
  • USE SHORT A (6”) LENGTH OF INSULATED HOSE FROM HYD. MOTOR HIGH PRESSURE SIDE TO PUMP ALSO RETURN LINE IF NOT RUBBER
  • ZINCS ARE AN IMPORTANT PART OF BOAT GALVANIC PROTECTION AS WELL AS MAINTAININGTHE CORRECT FIELD AROUND THE VESSEL
  • CLEAN ZINCS WITH A QUALITY STAINLESS STEEL BRUSH ONLY TO KEEP THEM ACTIVE
  • INSURE CANNONBALLS HAVE NO IMPURITIES IN THEM (PURE LEAD)
  • INSULATE CANNONBALLSFROM S/S TROLLING LINE USING HALIBUT GANGION (KINGS APX 6”)
  • CANNONBALLS SHOULD NOT BE STORED IN OR NEAR ALUMINIUM
  • IF AL. HOLDERS ARE USED — INSTALL INSULATED MATERIAL IN POCKETS (cg. INNERTUBE RUBBER)

 

LOW LINE READINGS:

POOR GURDIE INSULATION, ZINC ACTION
ETC, AS ABOVE LIST
LOW SALINITY
ELECTRICAL LEAKAGE